Availability: | |
---|---|
Quantity: | |
PBMS2000
DFUN
PBMS2000 Online Battery Monitoring Device
- Dedicated design for telecommunication 24V or 48V system
- 24/7 hours on-line monitoring & remote alarm
- Cost competitive solution, support Max. 1 string, total 120pcs batteries, or Max. 2 strings, Max. 60pcs batteries each string
- Measure Lead-Acid battery
- Multi communication protocol (Modbus-RTU, MODBUS-TCP, SNMP)
- Comply with IEEE 1188-2005
PBMS2000 Battery Monitoring System Main Controller
- Monitor battery string voltage, charge and discharge current
- Calculate battery string SOC
- Auto-balancing
- Auto-sensing for the battery sensor's ID address
- Set point alarm (upper limit / lower limit)
- Data collecting
- Data uploading function via build-in RS485 (Modbus-RTU) & Ethernet (Modbus-TCP or SNMP)
- Support 3rd party system
- Local display via HMI
- Accessories:
1) Hall sensor and cable: range from 0 ~ ±1000A with 2m cable
2) Communication cable: 5m with RJ11 port
PBAT61-02/PBAT61-06/PBAT61-12 Battery Cell Sensor
- PBAT61-02 for 2V battery, PBAT61-06 for 6V battery, PBAT61-12 for 12V battery
- Monitor individual battery voltage, internal temperature (negative pole), Impedance (ohmic value)
- Auto-balancing
7-inch Normal HMI (Optional)
- 7-inch touch-screen HMI for display and operation
- Real-time data inquiry:
1) Individual battery voltage, impedance, inner temperature, SOC, SOH
2) String voltage, charge and discharge current, SOC, balance degree
- Alarm data inquiry:
1) Real-time alarm status and related alarm information (faulty battery ID,
date/time, alarm reason, communication status, etc.)
2) 3000 alarm records for each string battery
PBMS2000 Online Battery Monitoring Device
- Dedicated design for telecommunication 24V or 48V system
- 24/7 hours on-line monitoring & remote alarm
- Cost competitive solution, support Max. 1 string, total 120pcs batteries, or Max. 2 strings, Max. 60pcs batteries each string
- Measure Lead-Acid battery
- Multi communication protocol (Modbus-RTU, MODBUS-TCP, SNMP)
- Comply with IEEE 1188-2005
PBMS2000 Battery Monitoring System Main Controller
- Monitor battery string voltage, charge and discharge current
- Calculate battery string SOC
- Auto-balancing
- Auto-sensing for the battery sensor's ID address
- Set point alarm (upper limit / lower limit)
- Data collecting
- Data uploading function via build-in RS485 (Modbus-RTU) & Ethernet (Modbus-TCP or SNMP)
- Support 3rd party system
- Local display via HMI
- Accessories:
1) Hall sensor and cable: range from 0 ~ ±1000A with 2m cable
2) Communication cable: 5m with RJ11 port
PBAT61-02/PBAT61-06/PBAT61-12 Battery Cell Sensor
- PBAT61-02 for 2V battery, PBAT61-06 for 6V battery, PBAT61-12 for 12V battery
- Monitor individual battery voltage, internal temperature (negative pole), Impedance (ohmic value)
- Auto-balancing
7-inch Normal HMI (Optional)
- 7-inch touch-screen HMI for display and operation
- Real-time data inquiry:
1) Individual battery voltage, impedance, inner temperature, SOC, SOH
2) String voltage, charge and discharge current, SOC, balance degree
- Alarm data inquiry:
1) Real-time alarm status and related alarm information (faulty battery ID,
date/time, alarm reason, communication status, etc.)
2) 3000 alarm records for each string battery