DFPE1000 Backup Power Monitoring Gateway

DFPE1000 Backup Power Monitoring Gateway is mainly for microcomputer rooms/distribution rooms/battery rooms/multi-site base stations etc. With UPS/EPS monitoring, power monitoring, environmental equipment monitoring (such as temperature and humidity…

Long Life Designed

Quality Guarantee

24/7 Guarantee

Support Guarantee

OEM Support

OEM is acceptable

▸ All-in-One, Monitor UPS/EPS, Battery, and Server Room Environment
▸ B/S structure, Build-in Web Server, achieve HTTP access
▸ Support Multiple Communication Protocol (SNMP, MODBUS-TCP, 4G) to Upload Data to 3rd Party System
▸ HMI for Local Display and Operation
▸ Auto-Sensing for Battery Sensor’s ID address, Save Engineering Time
▸ Support SMS for remote alarm, sound-light for local alarm
▸ Support on-line upgrade for easy technical support
▸ Anti-Interference Design to protect from UPS ripple interference, ensure stable operation
▸ 35mm DIN Rail Mount, can easily install at the site, no need for extra cabinet

DFPE1000 Backup Power Monitoring Gateway

Application

DFPE1000 Backup Power Monitoring Gateway applied to various applications, such as bank, railway transport, airport EPS,  highway EPS, medical institution etc.

Pain-points for the Industries

Influence of Error

Situation of equipment can not be known instantly, which will cause the inaccurate data and analyse report.

Inaccurate Data

Situation of equipment can not be known instantly, which will cause the inaccurate data and analyse report.

Lack of Guidance

If there is any error equipment. It will be hard to find out and analyse the problem and solution.

Influence of Error

It takes too much time and energy to check and maintain long-distance and seperate site.

High Cost

High labor cost and low efficiency.

Influence of Error
Inaccurate Data
 Lack of Guidance
Influence of Error
High Cost

Not only will the equipment error affect the business process, but also will lead to some dangerous accident.

Situation of equipment can not be known instantly, which will cause the inaccurate data and analyse report.

If there is any error equipment. It will be hard to find out and analyse the problem and solution.

It takes too much time and energy to check and maintain long-distance and seperate site.

High labor cost and low efficiency.

Monitoring Objects Including

DFPE1000 can real-time monitoring UPS, Battery, Smoke Sensor, T & H Sensor, Door Sensor, Water Leakage, Infrared etc.

UPS/EPS Monitor

1 UPS or 1 EPS

Battery Monitor

Monitor 1~2 string, each string ≤120 pcs

Temperature & Humidity Monitor

1 port temperature, 1 port humidity

DI Port for Digital Input Connecting Monitoring

4 x DI ports (smoke sensor, leaking sensor, infrared ray sensor……)

DO Port for Digital Output Signal

1 DO port for relay output signal

System Structure

Function

Monitor UPS/ EPS

— Communication Status
— input voltage, current, frequency
— output voltage, current, load
— Bypass backup time, voltage, SOC, Temperature

Monitor Backup Battery

— Individual Battery Voltage, Internal Temperature, Impedance
— Battery String Voltage, Charge and Discharge Current
— Calculate SOC and SOH
— Auto Balancing

Monitor Server Room Environment

— Temperature & Humidity
— Smoke Status
— Water Leakage Status (non-location)
— Infrared Status
— Door Status

Other functions

— Build in Web Server, Support SNMP, 4G, Modbus TCP to upload data
— Data Logging for 12 Months
— Setpoint Alarm for Parameters, Support SMS and Sound-light Alarm
— Report for All Deivce Parameters